emlin_catalog

Summary:

Concatenation of all of the dark time emission line file outputs

Naming Convention:

emlin_catalog.fits

Regex:

emlin_catalog\.fits

File Type:

FITS, 3 GB

Contents

Number

EXTNAME

Type

Contents

HDU0

IMAGE

Empty

HDU1

LSS

BINTABLE

Catalog data

FITS Header Units

HDU0

This HDU has no non-standard required keywords.

Empty HDU.

HDU1

EXTNAME = EMLIN

Concatenation of all of the dark time tile-based emission line file outputs (CROSS-REF)

Required Header Keywords

Required Header Keywords Table

KEY

Example Value

Type

Comment

NAXIS1

312

int

width of table in bytes

NAXIS2

11632889

int

number of rows in table

DESIDR

dr1

str

DESI Data Release

Required Data Table Columns

Name

Type

Units

Description

TARGETID

int64

Unique DESI target ID

OII_FLUX

float32

10**-17 erg/(s cm2)

Fitted flux for the [OII] doublet

OII_FLUX_IVAR

float32

10**+34 (s2 cm4) / erg2

Inverse variance of the fitted flux for the [OII] doublet

OII_SIGMA

float32

Angstrom

Fitted line width (in the observed frame) for the [OII] doublet

OII_SIGMA_IVAR

float32

Angstrom^-2

Inverse variance of the fitted line width (in the observed frame) for the [OII] doublet

OII_CONT

float32

10**-17 erg/(s cm2 Angstrom)

Continuum used for the fitting (fixed value) for the [OII] doublet

OII_CONT_IVAR

float32

10**+34 (s2 cm4 Angstrom2) / erg2

Inverse variance of the continuum for the [OII] doublet

OII_SHARE

float32

Fitted F1/(F0+F1) for the [OII] doublet, where F0 and F1 are the individual line fluxes

OII_SHARE_IVAR

float32

Inverse variance of the fitted F1/(F0+F1) for the [OII] doublet

OII_EW

float32

Angstrom

Fitted rest-frame equivalent width for the [OII] doublet

OII_EW_IVAR

float32

Angstrom^-2

Inverse variance of the fitted rest-frame equivalent width for the [OII] doublet

OII_CHI2

float32

Reduced chi2 of the fit for the [OII] doublet

OII_NDOF

int32

Number of degrees of freedom of the fit for the [OII] doublet

HDELTA_FLUX

float32

10**-17 erg/(s cm2)

Fitted flux for the HDELTA line

HDELTA_FLUX_IVAR

float32

10**+34 (s2 cm4) / erg2

Inverse variance of the fitted flux for the HDELTA line

HDELTA_SIGMA

float32

Angstrom

Fitted line width (in the observed frame) for the HDELTA line

HDELTA_SIGMA_IVAR

float32

Angstrom^-2

Inverse variance of the fitted line width (in the observed frame) for the HDELTA line

HDELTA_CONT

float32

10**-17 erg/(s cm2 Angstrom)

Continuum used for the fitting (fixed value) for the HDELTA line

HDELTA_CONT_IVAR

float32

10**+34 (s2 cm4 Angstrom2) / erg2

Inverse variance of the continuum for the HDELTA line

HDELTA_SHARE

float32

NaN (SHARE not relevant for HDELTA line)

HDELTA_SHARE_IVAR

float32

NaN (SHARE not relevant for HDELTA line)

HDELTA_EW

float32

Angstrom

Fitted rest-frame equivalent width for the HDELTA line

HDELTA_EW_IVAR

float32

Angstrom^-2

Inverse variance of the fitted rest-frame equivalent width for the HDELTA line

HDELTA_CHI2

float32

Reduced chi2 of the fit for the HDELTA line

HDELTA_NDOF

int32

Number of degrees of freedom of the fit for the HDELTA line

HGAMMA_FLUX

float32

10**-17 erg/(s cm2)

Fitted flux for the HGAMMA line

HGAMMA_FLUX_IVAR

float32

10**+34 (s2 cm4) / erg2

Inverse variance of the fitted flux for the HGAMMA line

HGAMMA_SIGMA

float32

Angstrom

Fitted line width (in the observed frame) for the HGAMMA line

HGAMMA_SIGMA_IVAR

float32

Angstrom^-2

Inverse variance of the fitted line width (in the observed frame) for the HGAMMA line

HGAMMA_CONT

float32

10**-17 erg/(s cm2 Angstrom)

Continuum used for the fitting (fixed value) for the HGAMMA line

HGAMMA_CONT_IVAR

float32

10**+34 (s2 cm4 Angstrom2) / erg2

Inverse variance of the continuum for the HGAMMA line

HGAMMA_SHARE

float32

NaN (SHARE not relevant for HGAMMA line)

HGAMMA_SHARE_IVAR

float32

NaN (SHARE not relevant for HGAMMA line)

HGAMMA_EW

float32

Angstrom

Fitted rest-frame equivalent width for the HGAMMA line

HGAMMA_EW_IVAR

float32

Angstrom^-2

Inverse variance of the fitted rest-frame equivalent width for the HGAMMA line

HGAMMA_CHI2

float32

Reduced chi2 of the fit for the HGAMMA line

HGAMMA_NDOF

int32

Number of degrees of freedom of the fit for the HGAMMA line

HBETA_FLUX

float32

10**-17 erg/(s cm2)

Fitted flux for the HBETA line

HBETA_FLUX_IVAR

float32

10**+34 (s2 cm4) / erg2

Inverse variance of the fitted flux for the HBETA line

HBETA_SIGMA

float32

Angstrom

Fitted line width (in the observed frame) for the HBETA line

HBETA_SIGMA_IVAR

float32

Angstrom^-2

Inverse variance of the fitted line width (in the observed frame) for the HBETA line

HBETA_CONT

float32

10**-17 erg/(s cm2 Angstrom)

Continuum used for the fitting (fixed value) for the HBETA line

HBETA_CONT_IVAR

float32

10**+34 (s2 cm4 Angstrom2) / erg2

Inverse variance of the continuum for the HBETA line

HBETA_SHARE

float32

NaN (SHARE not relevant for HBETA line)

HBETA_SHARE_IVAR

float32

NaN (SHARE not relevant for HBETA line)

HBETA_EW

float32

Angstrom

Fitted rest-frame equivalent width for the HBETA line

HBETA_EW_IVAR

float32

Angstrom^-2

Inverse variance of the fitted rest-frame equivalent width for the HBETA line

HBETA_CHI2

float32

Reduced chi2 of the fit for the HBETA line

HBETA_NDOF

int32

Number of degrees of freedom of the fit for the HBETA line

OIII_FLUX

float32

10**-17 erg/(s cm2)

Fitted flux for the [OIII] doublet

OIII_FLUX_IVAR

float32

10**+34 (s2 cm4) / erg2

Inverse variance of the fitted flux for the [OIII] doublet

OIII_SIGMA

float32

Angstrom

Fitted line width (in the observed frame) for the [OIII] doublet

OIII_SIGMA_IVAR

float32

Angstrom^-2

Inverse variance of the fitted line width (in the observed frame) for the [OIII] doublet

OIII_CONT

float32

10**-17 erg/(s cm2 Angstrom)

Continuum used for the fitting (fixed value) for the [OIII] doublet

OIII_CONT_IVAR

float32

10**+34 (s2 cm4 Angstrom2) / erg2

Inverse variance of the continuum for the [OIII] doublet

OIII_SHARE

float32

F1/(F0+F1) for the [OIII] doublet, where F0 and F1 are the individual line fluxes (SHARE value fixed during the fit)

OIII_SHARE_IVAR

float32

Infinite value, as SHARE is fixed during the fit

OIII_EW

float32

Angstrom

Fitted rest-frame equivalent width for the [OIII] doublet

OIII_EW_IVAR

float32

Angstrom^-2

Inverse variance of the fitted rest-frame equivalent width for the [OIII] doublet

OIII_CHI2

float32

Reduced chi2 of the fit for the [OIII] doublet

OIII_NDOF

int32

Number of degrees of freedom of the fit for the [OIII] doublet

HALPHA_FLUX

float32

10**-17 erg/(s cm2)

Fitted flux for the HALPHA line

HALPHA_FLUX_IVAR

float32

10**+34 (s2 cm4) / erg2

Inverse variance of the fitted flux for the HALPHA line

HALPHA_SIGMA

float32

Angstrom

Fitted line width (in the observed frame) for the HALPHA line

HALPHA_SIGMA_IVAR

float32

Angstrom^-2

Inverse variance of the fitted line width (in the observed frame) for the HALPHA line

HALPHA_CONT

float32

10**-17 erg/(s cm2 Angstrom)

Continuum used for the fitting (fixed value) for the HALPHA line

HALPHA_CONT_IVAR

float32

10**+34 (s2 cm4 Angstrom2) / erg2

Inverse variance of the continuum for the HALPHA line

HALPHA_SHARE

float32

NaN (SHARE not relevant for HALPHA line)

HALPHA_SHARE_IVAR

float32

NaN (SHARE not relevant for HALPHA line)

HALPHA_EW

float32

Angstrom

Fitted rest-frame equivalent width for the HALPHA line

HALPHA_EW_IVAR

float32

Angstrom^-2

Inverse variance of the fitted rest-frame equivalent width for the HALPHA line

HALPHA_CHI2

float32

Reduced chi2 of the fit for the HALPHA line

HALPHA_NDOF

int32

Number of degrees of freedom of the fit for the HALPHA line

LOCATION

int64

Location on the focal plane PETAL_LOC*1000 + DEVICE_LOC

TILEID

int64

Unique DESI tile ID

Notes and Examples